The code items a chimney report flags, and what it takes to clear each one
Clear a list of code items
Tell us what the report flagged, or that you have no report yet. We call back to set the inspection or the repair visit.
The code reference
NFPA 211 is published by the National Fire Protection Association and covers how chimneys, fireplaces and vents are built, inspected and kept in service. The California Residential Code carries matching rules for new work and repairs on houses, masonry chimneys and fireplaces included. When an inspection report calls something a code item, it is usually pointing at one of the rules below.
We handle each one the same way: find the rule, measure what is there, and put the gap between the two in writing.
- Clearance between brick and wood framing
- A liner in the flue
- Height above the roof
- Caps and spark arrestors
- Hearth size and trim near the opening
- Crown and flashing
Clearances and height
Brick carries heat, so the code keeps wood framing away from it. A masonry chimney inside the house wants two inches of air space to wood; one standing fully outside the wall wants one inch. In older Lakewood houses we sometimes find joists or blocking touching the brick in the attic, often buried under insulation. The fix is to cut the framing back, support it properly, and close the gap with a noncombustible seal.
Height matters for draft and for sparks. The code asks for three feet above the point where the chimney leaves the roof and two feet above anything within ten feet of it. A chimney cut down after quake damage, or one with a newer second storey beside it, can fall short. Raising it is a masonry job scoped from the inspection.
Liners, caps and spark arrestors
A masonry flue needs a liner: clay tile, a listed metal liner or a poured lining. A chimney with no liner, or with tiles split by a quake, fails this item. The usual fix is a stainless liner sized to what the chimney serves, priced from the camera footage.
A cap keeps rain and animals out and, with mesh, holds sparks in. Spark arrestor rules are stricter in wildfire areas, and most chimneys we work on get the mesh either way. The hearth must reach out past the opening by a set distance, more for larger openings, and wood trim near the opening is limited by how far it projects. Those are small masonry or carpentry fixes, priced once measured.
Crown, flashing and leaks
The crown is the cast slab on the brick around the flue, and its job under the code is to throw water clear of the chimney. A crown that is only a thin mortar skim, or one split by movement, lets water into the brick from above. Flashing seals the roof to the chimney, and when a stack shifts in a quake it is often the first thing to tear.
Leak work on a chimney has a published range, as does a cricket for a wide chimney that holds water on its high side. Crown and flashing work on their own are priced from what we find on the roof.
Prices for the common code fixes
These fixes repeat closely enough from house to house to carry a published range. Liners, crowns, dampers, chase covers and stand-alone flashing work get a written figure once we have photos of them.
- Finding and stopping a chimney leak
- $565 to $3,400
- Cricket on the high side of a wide stack
- $455 to $1,025
- Cricket and replacement flashing on every face
- $680 to $1,700
- Gas burning insert, fitted and vented
- $2,800 to $5,650
- Camera inspection to confirm the list
- $395
- Cap with mesh, fitted to the flue
- Quoted after we measure
Prices are installed. Structural items such as rebuilds and bracing are scoped from the camera inspection.
Code repair questions
Does an old chimney have to meet today's code?
An existing chimney is judged first on whether it is safe to use. When it is repaired, rebuilt or fitted with a new appliance, the new work is expected to follow current rules. The report says which items are safety issues and which are simply older than the code.
Which items should be fixed first?
Anything that lets heat reach wood, and brick that could fall, goes to the top. Water items come next, because they get worse each winter. Items that only affect looks come last.
Do I need a permit?
Some jobs, such as rebuilding a chimney or adding a gas insert, often need one; small repairs often do not. We tell you which applies to your job and who arranges it.
Can you work from another company's report?
Yes. We read it, check the items on site and price the fixes. If the report had no camera run and the items point inside the flue, we suggest one first.
Is a spark arrestor the same as a cap?
Not quite. The cap is the cover; the arrestor is the mesh around it that stops sparks leaving the flue. Most caps we fit carry the mesh.
A list of code items to clear?
Send what the report says, or ask for an inspection if there is no report yet, through the contact page.
Call (562) 449-0288